RTM 2300 – Multi-purpose Radon and Thoron Gas monitor

🚚 FREE SHIPPING on online orders over € 200 (Inside EU). Orders below € 199 depend on the final destination.

Contattaci

Description

Applications:

  • for measurements of airborne radon (²²² Rn) and thoron (²²⁰ Rn) activity concentrations
  • used at workplaces, in mining, and for geophysical investigations for measurements in air, soil air, water samples, etc.
  • public radiological safety measurements and environmental monitoring
  • radiological surveillance of places with sources of ionizing radiation

Features:

  • determination of radon and thoron activity concentrations
  • processor-controlled rotary vane pump
  • outstanding sensitivity and perfect separation of individual radon decay products using alpha spectroscopy; therefore, long-term contamination by 210Pb is excluded
  • no desiccant cartridge required
  • stores the complete alpha spectrum for each measured value
  • optional gamma probe (NaJ detector) (MCA 1024 channels)
  • numerous customer-specific additional sensors available
  • GPS module, optional water ingress protection, etc.
  • DAkkS-accredited calibration according to DIN EN ISO/IEC 17025:2018

Specifications

Radon measurement +Detector type: 4 x 200mm² Si detector with HV chambers +Internal volume: 250 ml (total volume of the internal air loop) +Range: 1 … 10 000 000 Bq/m³ +Accuracy: ≤ 5% +Sensitivity: 3 / 6.5 cpm/(kBq/m³) for fast / slow mode +Response time: 15 / 120 min for fast / slow mode +Results / Analysis: Radon concentration fast (excluding Po-214) and slow (including Po-214), thoron concentration, storage of record-related spectra and over time Gamma probe (option) +Connection: Connected to the front panel of the EQF 3300 by cable +Detector type: Sodium-Iodide (NaJ(Tl)) with integrated PMT and Bias, scintillation crystal 2" × 2" +MCA: 1024 channels +Energy range: 25 keV – 3 MeV +Resolution: < 7.5% (Cs-137) +Results / Analysis: Dose rate, net-activity of seven user-defined nuclides, storage of record-related spectra and time distribution +Probe dimensions: diameter 60 mm, length 260 mm +Cable: 5 m (optional 10 m) Additional sensors +Standard: Relative humidity 0 … 100%, uncertainty ± 2% +Temperature: -20 … 40°C, uncertainty ± 0.5°C +Barometric pressure: 800 … 1200 mbar, uncertainty 0.5% MW +Flow rate: 0 … 4 l/min, uncertainty ± 5% +Air analytics (option): CO, CO2, CH4, combustible gases, several ranges +Water analytics (option): pH value, redox potential, conductivity, etc. +Process (option): pressure, differential pressure, flow, velocity, etc. +Meteorological (option): wind direction, wind speed, etc. General +Sampling: simultaneous measurement with all detectors/sensors with respect to the selected sampling cycle +Sampling cycles: storage of up to 16 different sampling cycles with up to 32 steps (pre-defined or infinite repetition) +Integration interval: from 1 second to several weeks +Warning thresholds: warning thresholds for several parameters (up to 30 possible) +Data storage: SD card, 2 GByte +Display: color touchscreen, 6 × 9 cm +Interfaces: USB, RS232, 2x analog outputs (4–20 mA), 2x RS485 (one with Modbus RTU), 2x AUX (one used for RP-head), optional Wi-Fi. Two interfaces can work at the same time (see manual) +Power supply: 12 V NiMH rechargeable battery (>100 h continuous), mains adapter 100-240 V~ 50/60 Hz, 1.8 A +ATEX category: No +Dimensions / weight: 235 mm × 140 mm × 255 mm / 6 kg +Software: dVISION for control and data transfer (also via ZigBee-Wi-Fi), visualization, data management; dCONFIG for system configuration, creating / changing cycles (also via Net Monitors); dLIBRARY for nuclide library for NaJ gamma probe (option) +Extensions: available at internal connectors: 8 analog inputs, 3 counter inputs, 2 status inputs, 6 switch outputs, clock switch, PID regulator / analogous output +GPS: GPS coordinates are recorded and stored together with the measurement results. GIS-compatible *.kml files can be exported (can be opened by Google Earth). Antenna fixed on the front panel +Environmental conditions: 0 … 40°C; 0 … 95% rH, non-condensing; 800 … 1100 mbar

Resources

User Manul (english) Specifications (english) Software  

Warranty

SARAD GmbH provides a general 24-month warranty for customers in the European Union countries and 12 months for customers outside of the EU. The warranty period begins with the receipt of the goods by the customer. We reserve the right to rectification.

Reviews

There are no reviews yet

Be the first to review “RTM 2300 – Multi-purpose Radon and Thoron Gas monitor”

Your email address will not be published. Required fields are marked *

The new RTM 2300 is a professional multi-purpose radon/thoron gas monitor designed for precise, reliable, and versatile measurements in air, soil air, water samples, and environmental and radiological monitoring applications. Thanks to its outstanding sensitivity, high-performance alpha spectroscopy, and processor-controlled rotary vane pump, the instrument ensures excellent separation of radon decay products and accurate results even in the most demanding applications.

The RTM 2300 stores the complete alpha spectrum for each measurement and can be equipped with an optional gamma probe, customer-specific additional sensors, a GPS module, and optional water ingress protection. Its wide range of communication interfaces, color touchscreen display, and DAkkS-accredited calibration according to DIN EN ISO/IEC 17025:2018 make it an advanced solution for professional field and laboratory use.